Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Ultramid® A3WC8 - PA66-CF40 - BASF

Material Data Center offers the following functions for Ultramid® A3WC8:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Ultramid A datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts
Ultramid® A3WC8 is a 40 wt. % short carbon fiber reinforced, heat stabilized, high flow PA66 injection molding grade.
Mechanical propertiesdry / condUnitTest Standard
ISO Data
Tensile Modulus 38100 / 27400 MPa ISO 527
Stress at break 295 / 255 MPa ISO 527
Strain at break 1.2 / 2.1 % ISO 527
Charpy impact strength, +23°C 84 / - kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 11 / - kJ/m² ISO 179/1eA
Thermal propertiesdry / condUnitTest Standard
ISO Data
Temp. of deflection under load, 1.80 MPa 256 / * °C ISO 75-1/-2
Electrical propertiesdry / condUnitTest Standard
ISO Data
Volume resistivity 100 / - Ohm*m IEC 62631-3-1
Other propertiesdry / condUnitTest Standard
Density 1330 / - kg/m³ ISO 1183
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Regional Availability
North America
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.